Cardiovascular · 510(k) · 2023

ZEUS System

iRhythm Technologies, Inc.. Cleared by FDA on 15 February 2023 under submission K222389, product code DQK (computer, diagnostic, programmable). What FDA's record says, in FDA's words.

Device record · K222389

  1. Device. ZEUS SystemDEVICE
  2. Company. iRhythm Technologies, Inc.COMPANY
  3. Decision. 15 February 2023, 510(k), substantially equivalent (traditional review); received 8 August 2022DECISION
  4. Panel. CardiovascularPANEL
  5. Product code. DQK, Computer, Diagnostic, ProgrammableCODE
  6. Regulation. 21 CFR 870.1425, Class IIREG
  7. Source. FDA database entry · decision document (7 pages)SOURCE

Retrieved · the fields above are FDA's; the statement below was copied from the decision document on that day.

What FDA cleared it for

The Indications for Use statement, verbatim, from the decision document.

The device is intended to capture, analyze and report symptomatic and asymptomatic cardiac events and continuous electrocardiogram information for long-term monitoring. After wear, ECG data from compatible monitoring devices is processed and analyzed by the ZEUS System. A final report is generated on the beat-to-beat information from the entire ECG recording. For the Zio AT service, the ZEUS System supports the capture and analysis of automatically-detected arrhythmia events, as well as the analysis of uploaded patient-triggered events. The ZEUS System is indicated for use on patients 18 years or older who may be asymptomatic or who may suffer from transient symptoms such as palpitations, shortness of breath, dizziness, light-headedness, pre-syncope, syncope, fatigue, or anxiety and patients who are asymptomatic. The reports are provided for review by the intended user to render a diagnosis based on clinical judgment and experience. It is not intended for use on critical care patients.

K222389, FDA decision document · source

What the statement says

Pattern matches on the Indications for Use text. Each line is a fact that the text contains the words, not a finding about the device.

Adverse-event reports in MAUDE, by product code

As of , MAUDE held 4,558 reports filed against devices carrying product code DQK. That code is shared by every device of this type, not this device alone, and MAUDE reports are submitted by manufacturers, facilities and the public without FDA verification. The latest reports, in the reporter’s words:

30 September 2026 · Malfunction · QUANTIEN · Abbott Medical · report 2184149-2026-00257

During a fractional flow reserve procedure with QUANTIEN, it was noted that the PA signals were not appearing on the monitor leading to the procedure being cancelled. There were no adverse patient consequences.

29 September 2026 · Malfunction · Smart Pressure Controller · Edwards LifeSciences · report 2015691-2026-18928

29 September 2026 · Malfunction · Smart Pressure Controller · Edwards LifeSciences · report 2015691-2026-18932

29 September 2026 · Malfunction · Smart Pressure Controller · Edwards LifeSciences · report 2015691-2026-18933

29 September 2026 · Malfunction · Smart Pressure Controller · Edwards LifeSciences · report 2015691-2026-18934

Where this fits

This page is a record, not medical advice and not a safety rating. It copies FDA's fields and FDA's statement, and lists what the statement's text mentions. Read the labeling before relying on any of it.

More devices under product code DQK, in Cardiovascular, from iRhythm Technologies, Inc., or cleared in 2023. The whole record is at FDA AI-enabled medical devices.