Cardiovascular · 510(k) · 2025

Volta AF-Xplorer

Volta Medical. Cleared by FDA on 9 May 2025 under submission K243812, product code DQK (computer, diagnostic, programmable). What FDA's record says, in FDA's words.

Device record · K243812

  1. Device. Volta AF-XplorerDEVICE
  2. Company. Volta Medical (FR)COMPANY
  3. Decision. 9 May 2025, 510(k), substantially equivalent (traditional review); received 11 December 2024DECISION
  4. Panel. CardiovascularPANEL
  5. Product code. DQK, Computer, Diagnostic, ProgrammableCODE
  6. Regulation. 21 CFR 870.1425, Class IIREG
  7. Source. FDA database entry · decision document (11 pages)SOURCE

Retrieved · the fields above are FDA's; the statement below was copied from the decision document on that day.

What FDA cleared it for

The Indications for Use statement, verbatim, from the decision document.

The Volta AF-Xplorer assists operators in the real -time manual or automatic annotation of 3D anatomical and electrical maps of human atria for the presence of multipolar intra -cardiac atrial electrograms exhibiting spatiotemporal dispersion during atrial fibrillation or atrial tachycardia. Differences between subject and predicate intended use: The intended use / indications for use of the subject and predicate devices are identical with the exception that the qualifying language related to the clinical significance of the device has been removed based upon the results of the Tailored-AF clinical study which provide new clinical evidence related to the device safety, effectiveness and performance. The updated indications for use statement and additions to the product labeling do not alter the

K243812, FDA decision document · source

What the statement says

Pattern matches on the Indications for Use text. Each line is a fact that the text contains the words, not a finding about the device.

Adverse-event reports in MAUDE, by product code

As of , MAUDE held 4,558 reports filed against devices carrying product code DQK. That code is shared by every device of this type, not this device alone, and MAUDE reports are submitted by manufacturers, facilities and the public without FDA verification. The latest reports, in the reporter’s words:

30 September 2026 · Malfunction · QUANTIEN · Abbott Medical · report 2184149-2026-00257

During a fractional flow reserve procedure with QUANTIEN, it was noted that the PA signals were not appearing on the monitor leading to the procedure being cancelled. There were no adverse patient consequences.

29 September 2026 · Malfunction · Smart Pressure Controller · Edwards LifeSciences · report 2015691-2026-18928

29 September 2026 · Malfunction · Smart Pressure Controller · Edwards LifeSciences · report 2015691-2026-18932

29 September 2026 · Malfunction · Smart Pressure Controller · Edwards LifeSciences · report 2015691-2026-18933

29 September 2026 · Malfunction · Smart Pressure Controller · Edwards LifeSciences · report 2015691-2026-18934

Where this fits

This page is a record, not medical advice and not a safety rating. It copies FDA's fields and FDA's statement, and lists what the statement's text mentions. Read the labeling before relying on any of it.