Radiology · 510(k) · 2026

uSONIQUE Nova, uSONIQUE Nova Elite, uSONIQUE Vita, uSONIQUE Vita Elite, uSONIQUE Grace, uSONIQUE Grace Elite

Wuhan United Imaging Healthcare Co.,Ltd. Cleared by FDA on 21 May 2026 under submission K253720, product code IYN (system, imaging, pulsed doppler, ultrasonic). What FDA's record says, in FDA's words.

Device record · K253720

  1. Device. uSONIQUE Nova, uSONIQUE Nova Elite, uSONIQUE Vita, uSONIQUE Vita Elite, uSONIQUE Grace, uSONIQUE Grace EliteDEVICE
  2. Company. Wuhan United Imaging Healthcare Co.,Ltd (CN)COMPANY
  3. Decision. 21 May 2026, 510(k), substantially equivalent (traditional review); received 24 November 2025DECISION
  4. Panel. RadiologyPANEL
  5. Product code. IYN, System, Imaging, Pulsed Doppler, UltrasonicCODE
  6. Regulation. 21 CFR 892.1550, Class IIREG
  7. Source. FDA database entry · decision document (24 pages)SOURCE

Retrieved · the fields above are FDA's; the statement below was copied from the decision document on that day.

What FDA cleared it for

The Indications for Use statement, verbatim, from the decision document.

The Ultrasonic Pulsed Doppler Imaging System is used for ultrasound scanning of the whole body. It is intended for use by qualified and trained healthcare professionals in a hospital or medical clinic to perform ultrasound diagnostic examinations, supporting the following clinical applications: Abdominal (including Renal, Gynecological, and Obstetric), P ediatric, Small Parts, Cranial ( Neonatal Cephalic, Adult Cephalic), Cardiac, Peripheral Vascular, Musculoskeletal, Urological. Modes of operation include: B Mode, M Mode, Color Mode, PW Mode, CW Mode, 3D/4D Mode, Strain Elastography Imaging, Shear Wave Elastography Imaging. Combined modes: B/M, B/Color, B/PW, B/Color/PW. Wuhan United Imaging Healthcare Co., Ltd. Te l: +86 (21) 67076888 Fax:+86 (21) 67076889 www.united-imaging.com 4 of 20

K253720, FDA decision document · source

What the statement says

Pattern matches on the Indications for Use text. Each line is a fact that the text contains the words, not a finding about the device.

Adverse-event reports in MAUDE, by product code

As of , MAUDE held 2,748 reports filed against devices carrying product code IYN. That code is shared by every device of this type, not this device alone, and MAUDE reports are submitted by manufacturers, facilities and the public without FDA verification. The latest reports, in the reporter’s words:

30 September 2026 · Malfunction · ACUSON Origin Ultrasound System · Siemens Medical Solutions USA, Inc. · report 3023245-2026-00096

30 September 2026 · Malfunction · ACUSON Sequoia Ultrasound System · Siemens Medical Solutions USA, Inc. · report 3023245-2026-00097

30 September 2026 · Malfunction · AFFINITI 30 · Philips Ultrasound, Inc · report 3019216-2026-100325

30 September 2026 · Injury · EPIQ 5G · Philips Ultrasound, Inc · report 3019216-2026-100326

29 September 2026 · Malfunction · ACUSON Juniper · Siemens Medical Solutions USA, Inc. · report 3023245-2026-00091

One of the patient exams performed on the Juniper system displays an "Unarchived" error message and they are unable to send this study to PACS. All other exams performed before are after this one are transferring over to the PACS as expected without any errors. The problem occurred after a Breast study was completed and the user tried to send it over to the network PACS. TSE worked with the customer and she confirmed that the problem cannot be reproduced, as it only is affecting this one exam. […]

Where this fits

This page is a record, not medical advice and not a safety rating. It copies FDA's fields and FDA's statement, and lists what the statement's text mentions. Read the labeling before relying on any of it.

More devices under product code IYN, in Radiology, from Wuhan United Imaging Healthcare Co.,Ltd, or cleared in 2026. The whole record is at FDA AI-enabled medical devices.

A device's authorized use is a sentence the record can be read against. What Apodicta does on a medical record is that reading: every line of a note, a claim or a report proved to its source or held, before it renders.

Show me on one of my files →

This device is authorized for a stated use. See a record read against what it must prove, on your own file.

Show me on my files