Radiology · 510(k) · 2019

SIS Software Version 3.6.0

Surgical Information Sciences, Inc.. Cleared by FDA on 13 September 2019 under submission K192304, product code LLZ (system, image processing, radiological). What FDA's record says, in FDA's words.

Device record · K192304

  1. Device. SIS Software Version 3.6.0DEVICE
  2. Company. Surgical Information Sciences, Inc.COMPANY
  3. Decision. 13 September 2019, 510(k), substantially equivalent (special review); received 23 August 2019DECISION
  4. Panel. RadiologyPANEL
  5. Product code. LLZ, System, Image Processing, RadiologicalCODE
  6. Regulation. 21 CFR 892.2050, Class IIREG
  7. Source. FDA database entry · decision document (6 pages)SOURCE

Retrieved · the fields above are FDA's; the statement below was copied from the decision document on that day.

What FDA cleared it for

The Indications for Use statement, verbatim, from the decision document.

SIS Software is an application intended for use in the viewing, presentation and documentation of medical imaging, including different modules for image processing, image fusion, and intraoperative functional planning where the 3D output can be used with stereotactic image guided surgery or other devices for further processing and visualization. The device can be used in conjunction with other clinical methods as an aid in visualization of the subthalamic nuclei (STN). Typical users of the SIS Software are medical professionals, including but not limited to surgeons, neurologists and radiologists.

K192304, FDA decision document · source

What the statement says

Pattern matches on the Indications for Use text. Each line is a fact that the text contains the words, not a finding about the device.

Adverse-event reports in MAUDE, by product code

As of , MAUDE held 19,970 reports filed against devices carrying product code LLZ. That code is shared by every device of this type, not this device alone, and MAUDE reports are submitted by manufacturers, facilities and the public without FDA verification. The latest reports, in the reporter’s words:

30 September 2026 · Malfunction · IntelliSpace Cardiovascular · Philips Medical Systems Nederland B.V. · report 3003768277-2026-101631

Philips received a complaint on the IntelliSpace Cardiovascular (ISCV) indicating that the ISCV could only be accessed in Web-Only mode on the workstation. The device was in clinical use at the time of the event, and no adverse events or harm were reported in the complaint ((b)(4)).Philips has started an investigation of this complaint.

30 September 2026 · Malfunction · IntelliSpace Cardiovascular · Philips Medical Systems Nederland B.V. · report 3003768277-2026-101632

Philips received a complaint on the IntelliSearch Cardiovascular (ISCV) indicating that customer reported that study retrieval from the archive was either failing or taking an excessively long time to complete. The device was in clinical use at the time of the event, and no adverse events or harm were reported in the complaint (b)(4).Philips has started an investigation of this complaint.

30 September 2026 · Malfunction · IntelliSpace CardioVascular · Philips Medical Systems Nederland B.V. · report 3003768277-2026-101634

Philips identified a software defect in ISCV (IntelliSpace Cardiovascular) system wherein the user was reported that DICOM import crashed occasionally as there was a PDFClinicalContentExecuter error.. The device was in clinical use at the time of event.Based on the new information that Philips became aware, this has been determined to be a reportable malfunction. Under specific circumstances, it could potentially lead to delayed diagnosis. Given the defect¿s nature and its potential impact on […]

30 September 2026 · Malfunction · IntelliSpace CardioVascular · Philips Medical Systems Nederland B.V. · report 3003768277-2026-101635

Philips identified a software defect in ISCV (IntelliSpace Cardiovascular) system wherein the user could not save the findings. The device was in clinical use at the time of event. Based on the new information that Philips became aware, this has been determined to be a reportable malfunction. Under specific circumstances, it could potentially lead to delayed diagnosis. Given the defect¿s nature and its potential impact on clinical decision-making if it were to recur, it is determined that this […]

30 September 2026 · Malfunction · IntelliSpace Cardiovascular · Philips Medical Systems Nederland B.V. · report 3003768277-2026-101636

Philips identified a software defect in ISCV (IntelliSpace Cardiovascular) system wherein user reported that it was not possible to view previous studies in Echo Module. The device was in clinical use at the time of event. Based on the new information that Philips became aware, this has been determined to be a reportable malfunction. Under specific circumstances, it could potentially lead to delayed diagnosis. Given the defect¿s nature and its potential impact on clinical decision-making if it […]

Where this fits

This page is a record, not medical advice and not a safety rating. It copies FDA's fields and FDA's statement, and lists what the statement's text mentions. Read the labeling before relying on any of it.

More devices under product code LLZ, in Radiology, from Surgical Information Sciences, Inc., or cleared in 2019. The whole record is at FDA AI-enabled medical devices.