Radiology · 510(k) · 2025
QP-Prostate CAD
Quibim S.L.. Cleared by FDA on 18 March 2025 under submission K242683, product code QDQ (radiological computer assisted detection/diagnosis software for lesions suspicious for cancer). What FDA's record says, in FDA's words.
Device record · K242683
- Device. QP-Prostate CADDEVICE
- Company. Quibim S.L. (ES)COMPANY
- Decision. 18 March 2025, 510(k), substantially equivalent (traditional review); received 6 September 2024DECISION
- Panel. RadiologyPANEL
- Product code. QDQ, Radiological Computer Assisted Detection/Diagnosis Software For Lesions Suspicious For CancerCODE
- Regulation. 21 CFR 892.2090, Class IIREG
- Source. FDA database entry · decision document (12 pages)SOURCE
Retrieved · the fields above are FDA's; the statement below was copied from the decision document on that day.
What FDA cleared it for
The Indications for Use statement, verbatim, from the decision document.
QP-Prostate CAD is a Computed Aided Detection and Diagnosis (CADe/CADx) image processing software that automatically detects and identifies suspected lesions in the prostate gland based on bi-parametric prostate MRI. The software is intended to be used as a concurrent read by physicians with proper training in a clinical setting as an aid for interpreting prostate MRI studies. The results can be displayed in a variety of DICOM outputs, including identified suspected lesions marked as an overlay onto source MR images. The output can be displayed on third-party DICOM workstations and Picture Archive and Communication Systems (PACS). Patient management decisions should not be based solely on the results of QP-Prostate CAD. Intended patient population: Patients above 40 years with prostate MR imaging.
The product code's definition, from FDA's classification record. A radiological computer assisted detection and diagnostic software for suspected lesions is an image processing device intended to aid in the detection, localization, and characterization of lesions suspicious for cancer on acquired medical images (e.g., mammography , MR, CT, ultrasound, radiography). The device detects, identifies and characterizes lesions suspicious for cancer based on features or information extracted from the images, and may provide information about the presence, location, and characteristics of the lesion to the user. Primary diagnostic and patient management decisions are made by the clinical user.
What the statement says
Pattern matches on the Indications for Use text. Each line is a fact that the text contains the words, not a finding about the device.
- Modalities namedMRI
- Mentionsdetection or identification of findings
- Mentionsa diagnostic claim
Adverse-event reports in MAUDE, by product code
As of , MAUDE held 0 reports filed against devices carrying product code QDQ. That code is shared by every device of this type, not this device alone, and MAUDE reports are submitted by manufacturers, facilities and the public without FDA verification.
Where this fits
This page is a record, not medical advice and not a safety rating. It copies FDA's fields and FDA's statement, and lists what the statement's text mentions. Read the labeling before relying on any of it.
More devices under product code QDQ, in Radiology, from Quibim S.L., or cleared in 2025. The whole record is at FDA AI-enabled medical devices.
A device's authorized use is a sentence the record can be read against. What Apodicta does on a medical record is that reading: every line of a note, a claim or a report proved to its source or held, before it renders.