Radiology · 510(k) · 2020
Neuro.Al Algorithm
TeraRecon, Inc.. Cleared by FDA on 6 November 2020 under submission K200750, product code LLZ (system, image processing, radiological). What FDA's record says, in FDA's words.
Device record · K200750
- Device. Neuro.Al AlgorithmDEVICE
- Company. TeraRecon, Inc.COMPANY
- Decision. 6 November 2020, 510(k), substantially equivalent (special review); received 23 March 2020DECISION
- Panel. RadiologyPANEL
- Product code. LLZ, System, Image Processing, RadiologicalCODE
- Regulation. 21 CFR 892.2050, Class IIREG
- Source. FDA database entry · decision document (9 pages)SOURCE
Retrieved · the fields above are FDA's; the statement below was copied from the decision document on that day.
What FDA cleared it for
The Indications for Use statement, verbatim, from the decision document.
The Neuro.AI Algorithm is an algorithm for use by trained profe ssionals, including but not limited to physicians, surgeons and medical clinicians. The Neuro.AI Algorithm is a st andalone image processing softwar e device that can be deployed as a Microsoft Windows executable on off-the-shelf hardware or as a containerized application (e.g., a Docker container) that runs on off-the-shelf hardware or on a cloud platform. Data and images are acquired via DICOM compliant imaging devices. DICOM results may be exported, combined with or utilized by other DICOM-compliant systems and results. The Neuro.AI Algorithm provide s analysis capabilities for static, functional, dynamic and derived imaging datasets acquired with CT or MRI. It can be used for the analys is of dynamic brain perfusion image data, showing properties of changes in contrast over time. This funct ionality includes calculation of parameters related to brain tissue perfusion, vascular assessment and tissue blood volume and other parametric maps with or without the ventricles included in the calculation. The algorithm also includes volume reformat in various orientations, rotational MIP 3D batch while removing the skull. This “tumble view” allows qualitative review of vascular structure in direct correlation to the perfusion maps for comprehensive review. K200750 3 The results of the Neuro.AI Algorithm can be delivered to the e nd-user through image viewers such as TeraRecon’s Aquarius iNtuition system, TeraRecon’s […]
What the statement says
Pattern matches on the Indications for Use text. Each line is a fact that the text contains the words, not a finding about the device.
- Modalities namedCT, MRI
- Mentionsmeasurement or quantification
Adverse-event reports in MAUDE, by product code
As of , MAUDE held 19,970 reports filed against devices carrying product code LLZ. That code is shared by every device of this type, not this device alone, and MAUDE reports are submitted by manufacturers, facilities and the public without FDA verification. The latest reports, in the reporter’s words:
30 September 2026 · Malfunction · IntelliSpace Cardiovascular · Philips Medical Systems Nederland B.V. · report 3003768277-2026-101631
Philips received a complaint on the IntelliSpace Cardiovascular (ISCV) indicating that the ISCV could only be accessed in Web-Only mode on the workstation. The device was in clinical use at the time of the event, and no adverse events or harm were reported in the complaint ((b)(4)).Philips has started an investigation of this complaint.
30 September 2026 · Malfunction · IntelliSpace Cardiovascular · Philips Medical Systems Nederland B.V. · report 3003768277-2026-101632
Philips received a complaint on the IntelliSearch Cardiovascular (ISCV) indicating that customer reported that study retrieval from the archive was either failing or taking an excessively long time to complete. The device was in clinical use at the time of the event, and no adverse events or harm were reported in the complaint (b)(4).Philips has started an investigation of this complaint.
30 September 2026 · Malfunction · IntelliSpace CardioVascular · Philips Medical Systems Nederland B.V. · report 3003768277-2026-101634
Philips identified a software defect in ISCV (IntelliSpace Cardiovascular) system wherein the user was reported that DICOM import crashed occasionally as there was a PDFClinicalContentExecuter error.. The device was in clinical use at the time of event.Based on the new information that Philips became aware, this has been determined to be a reportable malfunction. Under specific circumstances, it could potentially lead to delayed diagnosis. Given the defect¿s nature and its potential impact on […]
30 September 2026 · Malfunction · IntelliSpace CardioVascular · Philips Medical Systems Nederland B.V. · report 3003768277-2026-101635
Philips identified a software defect in ISCV (IntelliSpace Cardiovascular) system wherein the user could not save the findings. The device was in clinical use at the time of event. Based on the new information that Philips became aware, this has been determined to be a reportable malfunction. Under specific circumstances, it could potentially lead to delayed diagnosis. Given the defect¿s nature and its potential impact on clinical decision-making if it were to recur, it is determined that this […]
30 September 2026 · Malfunction · IntelliSpace Cardiovascular · Philips Medical Systems Nederland B.V. · report 3003768277-2026-101636
Philips identified a software defect in ISCV (IntelliSpace Cardiovascular) system wherein user reported that it was not possible to view previous studies in Echo Module. The device was in clinical use at the time of event. Based on the new information that Philips became aware, this has been determined to be a reportable malfunction. Under specific circumstances, it could potentially lead to delayed diagnosis. Given the defect¿s nature and its potential impact on clinical decision-making if it […]