Radiology · 510(k) · 2020

MRCAT brain

Philips Medical Systems MR Finland. Cleared by FDA on 24 January 2020 under submission K193109, product code MUJ (system, planning, radiation therapy treatment). What FDA's record says, in FDA's words.

Device record · K193109

  1. Device. MRCAT brainDEVICE
  2. Company. Philips Medical Systems MR Finland (FI)COMPANY
  3. Decision. 24 January 2020, 510(k), substantially equivalent (traditional review); received 8 November 2019DECISION
  4. Panel. RadiologyPANEL
  5. Product code. MUJ, System, Planning, Radiation Therapy TreatmentCODE
  6. Regulation. 21 CFR 892.5050, Class IIREG
  7. Source. FDA database entry · decision document (16 pages)SOURCE

Retrieved · the fields above are FDA's; the statement below was copied from the decision document on that day.

What FDA cleared it for

The Indications for Use statement, verbatim, from the decision document.

MRCAT brain is indicated for radiotherapy treatment planning for primary and metastatic brain tumor patients. Fundamental Scientific Technology: MRCAT brain functionality is implemented as a software plug-in for the MR main software and it contains the following main features: 1) Automatic post-processing tool delivering MRCAT images 2) Examcard with mDixon imaging protocol 3) DICOM export of MRCAT image. MRCAT Image Generation MRCAT images are generated with an ExamCard post-processing step, which uses the images from the previous mDixon scan. The post-processing logic takes care of launching MRCAT algorithm executable calculating a new 3D MRCAT image. The post-processing is started once the acquired mDixon MR images have been reconstructed. The first step of MRCAT generation is to pre-process the images to ensure that the MRCAT source images have consistent intensities. The intensity normalized images are then used as input in a convolutional neural network (CNN). The CNN is trained using matched pairs of CT and MRCAT source images. The training of the CNN is locked and is not adapted during use. The output of the CNN is post-processed to create images in CT values. The generated MRCAT images are checked for correctness to ensure validity of the generated MRCAT for radiation treatment. The sanity checks ensure that the imaging field of view has been positioned correctly and that the MRCAT body outline matches that of the MR. The HU values for the Philips Medical Systems […]

K193109, FDA decision document · source

What the statement says

Pattern matches on the Indications for Use text. Each line is a fact that the text contains the words, not a finding about the device.

Adverse-event reports in MAUDE, by product code

As of , MAUDE held 807 reports filed against devices carrying product code MUJ. That code is shared by every device of this type, not this device alone, and MAUDE reports are submitted by manufacturers, facilities and the public without FDA verification. The latest reports, in the reporter’s words:

24 September 2026 · Malfunction · MONACO · Elekta Solutions AB · report 3015232217-2026-00031

The customer reported that the SRS Cone plan export for the counter clockwise beam is not being transferred correctly to MOSAIQ.

22 September 2026 · Malfunction · RayStation · RaySearch Laboratories AB (Publ) · report 3007774465-2026-00003

A user was preparing radiotherapy treatment of the right breast for a patient who had previously received RT to the left breast. The user performed a deformable registration of the two CT scans (prior treatment and current) and mapped the dose onto the current planning CT to create a cumulative dose distribution. The user noticed that the dose in the left breast (from the prior treatment) appeared cut off as it was limited by the size of the dose grid used for the prior treatment. The patient […]

22 September 2026 · Malfunction · RayStation · RaySearch Laboratories AB (Publ) · report 3010034862-2026-00003

A user was preparing radiotherapy treatment of the right breast for a patient who had previously received RT to the left breast. The user performed a deformable registration of the two CT scans (prior treatment and current) and mapped the dose onto the current planning CT to create a cumulative dose distribution. The user noticed that the dose in the left breast (from the prior treatment) appeared cut off as it was limited by the size of the dose grid used for the prior treatment. The patient […]

15 July 2026 · Malfunction · PLANONE 1 · COSYLAB, JSC, CONTROL SYSTEM LABORATORY · report 3014425747-2026-00001

DURING TREATMENT PLAN PREPARATION FOR A PATIENT, IT WAS DISCOVERED THAT COUCH SHIFTS (TREATMENT COUCH TRANSLATIONS REQUIRED TO MOVE THE PATIENT FROM THE REFERENCE/SCANNED POSITION TO THE TREATMENT POSITION) DISPLAYED IN PLANONE DIFFERED FROM THOSE DISPLAYED IN ARIA/ECLIPSE WHEN A PLAN CREATED IN PLANONE WAS TRANSFERRED TO ARIA FOR SCHEDULING. NO PATIENT HARM OCCURRED, AS THE INCONSISTENCY WAS IDENTIFIED DURING THE PLAN PREPARATION PHASE BEFORE TREATMENT DELIVERY. INVESTIGATION IDENTIFIED THE […]

2 June 2026 · Malfunction · MONACO · ELEKTA SOLUTIONS AB · report 3015232217-2026-00016

THE CUSTOMER REPORTED THAT THE NUMBERING OF THE FIRST MRI IN MONACO ALWAYS STARTS WITH MR2, AND ONLY THE SECOND MRI THEN BEARS THE NUMBER MR1.

Where this fits

This page is a record, not medical advice and not a safety rating. It copies FDA's fields and FDA's statement, and lists what the statement's text mentions. Read the labeling before relying on any of it.

More devices under product code MUJ, in Radiology, or cleared in 2020. The whole record is at FDA AI-enabled medical devices.

A device's authorized use is a sentence the record can be read against. What Apodicta does on a medical record is that reading: every line of a note, a claim or a report proved to its source or held, before it renders.

Show me on one of my files →

This device is authorized for a stated use. See a record read against what it must prove, on your own file.

Show me on my files