Radiology · 510(k) · 2020

Hepatic VCAR

GE Medical Systems SCS. Cleared by FDA on 20 March 2020 under submission K193281, product code JAK (system, x-ray, tomography, computed). What FDA's record says, in FDA's words.

Device record · K193281

  1. Device. Hepatic VCARDEVICE
  2. Company. GE Medical Systems SCS (FR)COMPANY
  3. Decision. 20 March 2020, 510(k), substantially equivalent (traditional review); received 27 November 2019DECISION
  4. Panel. RadiologyPANEL
  5. Product code. JAK, System, X-Ray, Tomography, ComputedCODE
  6. Regulation. 21 CFR 892.1750, Class IIREG
  7. Source. FDA database entry · decision document (6 pages)SOURCE

Retrieved · the fields above are FDA's; the statement below was copied from the decision document on that day.

What FDA cleared it for

The Indications for Use statement, verbatim, from the decision document.

Hepatic VCAR is a CT image analysis software package that allows the analysis and visualization of Liver CT data derived from DICOM 3.0 compliant CT scans. Hepatic VCAR is designed for the purpose of assessing liver morphology, including liver lesion, provided the lesion has different CT appearance from surrounding liver tissue; and its change over time through automated tools for liver, liver lobe, liver segments and liver lesion segmentation and measurement. It is intended for use by clinicians to process, review, archive, print and distribute liver CT studies. This software will assist the user by providing initial 3D segmentation, vessel analysis, visualization, and quantitative analysis of liver anatomy. The user has the ability to adjust the contour and confirm the final segmentation.

K193281, FDA decision document · source

What the statement says

Pattern matches on the Indications for Use text. Each line is a fact that the text contains the words, not a finding about the device.

Adverse-event reports in MAUDE, by product code

As of , MAUDE held 5,281 reports filed against devices carrying product code JAK. That code is shared by every device of this type, not this device alone, and MAUDE reports are submitted by manufacturers, facilities and the public without FDA verification. The latest reports, in the reporter’s words:

25 September 2026 · Malfunction · REVOLUTION EVO · GE MEDICAL SYSTEMS, LLC · report 50896044

The GE CT table wouldn't move during stroke. Patient had to be physically moved to resume scan, delay in care. GE CT table has had the same issues with the table working intermittently x 3 weeks. Multiple techs have worked on it and the same problem persists.

25 September 2026 · Malfunction · Needle Guide · Quantum Surgical SAS · report 3023140882-2026-00002

23 September 2026 · Malfunction · ILLUMISITE · COVIDIEN LP - SUPERDIMENSION INC · report 3004962788-2026-00087

It was reported that during the procedure, one locatable guide indicated as outside of the sensor sensing volume and another locatable guide had difficulty retracting from the extended working channel. The physician completed the superDimension portion of the case. No patient complications have been reported as a result of this event.

23 September 2026 · Other · NL4000 · Samsung HME America, Inc. · report 3004938766-2026-00043

23 September 2026 · Malfunction · ILLUMISITE · COVIDIEN LP - SUPERDIMENSION INC · report 3004962788-2026-00088

Where this fits

This page is a record, not medical advice and not a safety rating. It copies FDA's fields and FDA's statement, and lists what the statement's text mentions. Read the labeling before relying on any of it.

More devices under product code JAK, in Radiology, from GE Medical Systems SCS, or cleared in 2020. The whole record is at FDA AI-enabled medical devices.

A device's authorized use is a sentence the record can be read against. What Apodicta does on a medical record is that reading: every line of a note, a claim or a report proved to its source or held, before it renders.

Show me on one of my files →