Radiology · 510(k) · 2025

CogNet AI-MT+

Medcognetics, Inc.. Cleared by FDA on 11 December 2025 under submission K252482, product code QFM (radiological computer-assisted prioritization software for lesions). What FDA's record says, in FDA's words.

Device record · K252482

  1. Device. CogNet AI-MT+DEVICE
  2. Company. Medcognetics, Inc.COMPANY
  3. Decision. 11 December 2025, 510(k), substantially equivalent (traditional review); received 7 August 2025DECISION
  4. Panel. RadiologyPANEL
  5. Product code. QFM, Radiological Computer-Assisted Prioritization Software For LesionsCODE
  6. Regulation. 21 CFR 892.2080, Class IIREG
  7. Source. FDA database entry · decision document (13 pages)SOURCE

Retrieved · the fields above are FDA's; the statement below was copied from the decision document on that day.

What FDA cleared it for

The Indications for Use statement, verbatim, from the decision document.

The MedCognetics CogNet AI -MT+ software is a passive notification for prioritization- only, parallel -workflow software tool used by MQSA qualified interpreting physicians to prioritize patients with suspicious findings in a medical care environment. CogNet AI- MT+ utilizes an artificial intelligence algorithm to analyze DBT screening mammograms and flags those that are suggestive of the presence of at least one suspicious finding at the exam level. CogNet AI -MT+ produces an exam level output to a PACS/Workstation for flagging the suspicious study and allows for worklist prioritization. MQSA qualified interpreting physicians are responsible for reviewing each exam on a display approved for use in mammography, according to the current standard of care. The CogNet AI-MT+ device is limited to the categorization of exams, does not provide any diagnostic information beyond triage and prioritization, does not remove images from the interpreting physician’s worklist, and should not be used in lieu of full patient evaluation, or relied upon to make or confirm diagnosis. The CogNet AI -MT+ device is intended for use with DBT mammography exams acquired using validated equipment systems, only.

K252482, FDA decision document · source

The product code's definition, from FDA's classification record. Radiological computer-assisted prioritization software for lesions is an image processing device intended to aid in prioritization and triage of time sensitive patient detection and diagnosis based on the analysis of medical images acquired from radiological signal acquisition systems. The device identifies or prioritizes time sensitive imaging for review by prespecified clinical users based on software-based image analysis but does not provide information from the image analysis other than triage and notification.

What the statement says

Pattern matches on the Indications for Use text. Each line is a fact that the text contains the words, not a finding about the device.

Adverse-event reports in MAUDE, by product code

As of , MAUDE held 0 reports filed against devices carrying product code QFM. That code is shared by every device of this type, not this device alone, and MAUDE reports are submitted by manufacturers, facilities and the public without FDA verification.

Where this fits

This page is a record, not medical advice and not a safety rating. It copies FDA's fields and FDA's statement, and lists what the statement's text mentions. Read the labeling before relying on any of it.

More devices under product code QFM, in Radiology, from Medcognetics, Inc., or cleared in 2025. The whole record is at FDA AI-enabled medical devices.

A device's authorized use is a sentence the record can be read against. What Apodicta does on a medical record is that reading: every line of a note, a claim or a report proved to its source or held, before it renders.

Show me on one of my files →

This device is authorized for a stated use. See a record read against what it must prove, on your own file.

Show me on my files