Gastroenterology-Urology · 510(k) · 2024

CADDIE

Odin Medical Limited. Cleared by FDA on 24 July 2024 under submission K240044, product code QNP (gastrointesinal lesion software detection system). What FDA's record says, in FDA's words.

Device record · K240044

  1. Device. CADDIEDEVICE
  2. Company. Odin Medical Limited (GB)COMPANY
  3. Decision. 24 July 2024, 510(k), substantially equivalent (traditional review); received 5 January 2024DECISION
  4. Panel. Gastroenterology-UrologyPANEL
  5. Product code. QNP, Gastrointesinal Lesion Software Detection SystemCODE
  6. Regulation. 21 CFR 876.1520, Class IIREG
  7. Source. FDA database entry · decision document (21 pages)SOURCE

Retrieved · the fields above are FDA's; the statement below was copied from the decision document on that day.

What FDA cleared it for

The Indications for Use statement, verbatim, from the decision document.

The CADDIE computer-assisted detection device is intended to assist the gastroenterologist in detecting suspected colorectal polyps only. The gastroenterologist is responsible for reviewing CADDIE suspected polyp areas and confirming the presence or absence of a polyp based on their own medical judgment. CADDIE is not intended to replace a full patient evaluation, nor is it intended to be relied upon to make a primary interpretation of endoscopic procedures, medical diagnosis, or recommendations of treatment/course of action for patients. The CADDIE computer-assisted detection device is limited for use with standard white-light endoscopy imaging only.

K240044, FDA decision document · source

The product code's definition, from FDA's classification record. A gastrointestinal lesion software detection system is a computer-assisted detection device used in conjunction with endoscopy for the detection of abnormal lesions in the gastrointestinal tract. This device with advanced software algorithms brings attention to images to aid in the detection of lesions. The device may contain hardware to support interfacing with an endoscope.

What the statement says

Pattern matches on the Indications for Use text. Each line is a fact that the text contains the words, not a finding about the device.

Adverse-event reports in MAUDE, by product code

As of , MAUDE held 2 reports filed against devices carrying product code QNP. That code is shared by every device of this type, not this device alone, and MAUDE reports are submitted by manufacturers, facilities and the public without FDA verification. The latest reports, in the reporter’s words:

28 July 2026 · Malfunction · Endoscopy CAD system · SHIRAKAWA OLYMPUS CO., LTD. · report 3002808148-2026-25724

29 August 2024 · Malfunction · PENTAX · HOYA CORPORATION PENTAX TOKYO OFFICE · report 9610877-2024-00082

COVER OF THE NEW SAS-M10 MONITOR SMOKED DURING SWITCH ON THE FIRST TIME 08-AUG-2024_WE ASKED FOR FURTHER INFORMATION AND PICTURES NO FURTHER INFORMATION. TEH MONITOR WAS SWITCHED OFF AND SEND BACK TO PENTAX MEDICAL EMEA FOR REPLACEMENT. THIS EVENT OCCURRED AT THE TIME OF INSTALLATION. THERE WAS NO REPORT OF PATIENT HARM. THIS EVENT MEETS THE REQUIREMENTS FOR FDA REPORTABILITY; HOWEVER, SUBMISSION OF THIS REPORT DOES NOT CONSTITUTE AN ADMISSION THAT MEDICAL PERSONNEL, USER FACILITY, IMPORTER, […]

Where this fits

This page is a record, not medical advice and not a safety rating. It copies FDA's fields and FDA's statement, and lists what the statement's text mentions. Read the labeling before relying on any of it.

More devices under product code QNP, in Gastroenterology-Urology, from Odin Medical Limited, or cleared in 2024. The whole record is at FDA AI-enabled medical devices.

A device's authorized use is a sentence the record can be read against. What Apodicta does on a medical record is that reading: every line of a note, a claim or a report proved to its source or held, before it renders.

Show me on one of my files →

This device is authorized for a stated use. See a record read against what it must prove, on your own file.

Show me on my files