BriefCase, RIB Fractures Triage (RibFx)
Aidoc Medical, Ltd.. Cleared by FDA on 14 April 2021 under submission K202992, product code QFM (radiological computer-assisted prioritization software for lesions). What FDA's record says, in FDA's words.
Device record · K202992
- Device. BriefCase, RIB Fractures Triage (RibFx)DEVICE
- Company. Aidoc Medical, Ltd. (IL)COMPANY
- Decision. 14 April 2021, 510(k), substantially equivalent (traditional review); received 30 September 2020DECISION
- Panel. RadiologyPANEL
- Product code. QFM, Radiological Computer-Assisted Prioritization Software For LesionsCODE
- Regulation. 21 CFR 892.2080, Class IIREG
- Source. FDA database entry · decision document (9 pages)SOURCE
Retrieved · the fields above are FDA's; the statement below was copied from the decision document on that day.
What FDA cleared it for
The Indications for Use statement, verbatim, from the decision document.
BriefCase is a radiological computer aided triage and notification software indicated for use in the analysis of chest CTs (with or without contrast). The device is intended to assist hospital networks and appropriately trained medical specialists in workflow triage by flagging and communication of suspect cases of three or more acute Rib fracture (RibFx) pathologies. BriefCase uses an artificial intelligence algorithm to analyze images and flag suspect cases on a standalone desktop application in parallel to the ongoing standard of care image interpretation. The user is presented with notifications for suspect cases. Notifications include compressed preview images that are meant for informational purposes only and not intended for diagnostic use beyond notification. The device does not alter the original medical image and is not intended to be used as a diagnostic device. The results of BriefCase are intended to be used in conjunction with other patient information and based on their professional judgment, to assist with triage/prioritization of medical images. Notified clinicians are responsible for viewing full images per the standard of care.
The product code's definition, from FDA's classification record. Radiological computer-assisted prioritization software for lesions is an image processing device intended to aid in prioritization and triage of time sensitive patient detection and diagnosis based on the analysis of medical images acquired from radiological signal acquisition systems. The device identifies or prioritizes time sensitive imaging for review by prespecified clinical users based on software-based image analysis but does not provide information from the image analysis other than triage and notification.
What the statement says
Pattern matches on the Indications for Use text. Each line is a fact that the text contains the words, not a finding about the device.
- Mentionstriage or notification
- Mentionsa diagnostic claim
Adverse-event reports in MAUDE, by product code
As of , MAUDE held 0 reports filed against devices carrying product code QFM. That code is shared by every device of this type, not this device alone, and MAUDE reports are submitted by manufacturers, facilities and the public without FDA verification.
Where this fits
This page is a record, not medical advice and not a safety rating. It copies FDA's fields and FDA's statement, and lists what the statement's text mentions. Read the labeling before relying on any of it.
More devices under product code QFM, in Radiology, from Aidoc Medical, Ltd., or cleared in 2021. The whole record is at FDA AI-enabled medical devices.