Avenda Health AI Prostate Cancer Planning Software
Avenda Health, Inc.. Cleared by FDA on 22 November 2022 under submission K221624, product code POK (computer-assisted diagnostic software for lesions suspicious for cancer). What FDA's record says, in FDA's words.
Device record · K221624
- Device. Avenda Health AI Prostate Cancer Planning SoftwareDEVICE
- Company. Avenda Health, Inc.COMPANY
- Decision. 22 November 2022, 510(k), substantially equivalent (traditional review); received 6 June 2022DECISION
- Panel. RadiologyPANEL
- Product code. POK, Computer-Assisted Diagnostic Software For Lesions Suspicious For CancerCODE
- Regulation. 21 CFR 892.2060, Class IIREG
- Source. FDA database entry · decision document (13 pages)SOURCE
Retrieved · the fields above are FDA's; the statement below was copied from the decision document on that day.
What FDA cleared it for
The Indications for Use statement, verbatim, from the decision document.
The Avenda Health AI Prostate Cancer Planning Software is an artificial intelligence (AI)-based decision support software, indicated as an adjunct to the review of magnetic resonance (MR) prostate images and biopsy findings in the prostate oncological workflow. The Avenda Health AI Prostate Cancer Planning Software is designed to support the prostate oncological workflow by helping the user with the segmentation of MR image features, including the prostate; in the evaluation, quantification, and documentation of lesions; and in pre-planning for diagnostic and interventional procedures such as biopsy and/or soft tissue ablation. The device is intended to be used by physicians trained in the oncological workflow in a clinical setting for planning and guidance for clinical, interventional, diagnostic, and/or treatment procedures of the prostate. The Avenda Health AI Prostate Cancer Planning Software’s lesion characterization functions are intended for use on patients with a pathology-confirmed Gleason Grade Group (GGG) ≥ 2 lesion and for whom corresponding biopsy coordinate information have been uploaded. These functions are indicated for the evaluation of the extent of known disease. Extent of known disease refers to the boundary of a pathology confirmed lesion of GGG ≥ 2 for a particular patient. Specifically, using prostate MR images, biopsy, pathology, and clinical data, the device creates and displays a cancer map that assigns a probability to each voxel within the […]
The product code's definition, from FDA's classification record. Assist users in characterizing lesions identified on acquired medical images
What the statement says
Pattern matches on the Indications for Use text. Each line is a fact that the text contains the words, not a finding about the device.
- Modalities namedMRI
- Mentionsan adjunct to the clinician, not a replacement
- Mentionsdetection or identification of findings
- Mentionsmeasurement or quantification
- Mentionsa diagnostic claim
Adverse-event reports in MAUDE, by product code
As of , MAUDE held 1 report filed against devices carrying product code POK. That code is shared by every device of this type, not this device alone, and MAUDE reports are submitted by manufacturers, facilities and the public without FDA verification. The latest reports, in the reporter’s words:
15 January 2021 · Malfunction · QUANTX · report MW5098869
QUANTX SOFTWARE MAY ENTER INTO AN ERROR STATE IN WHICH MEDICAL IMAGES DISPLAYED TO THE USER ARE FROZEN IN PLACE. QUANTX SOFTWARE VERSION (B)(4) ENTER INTO AN ERROR STATE IN WHICH ONE VIEWPORT IS FROZEN IN PLACE. WHEN THIS ERROR OCCURS, QUANTX STOPS RESPONDING TO USER INPUTS TO MODIFY THE DISPLAY OF THE FROZEN IMAGE. THIS ERROR STATE IS REACHED THROUGH A SPECIFIC SEQUENCE OF KEYSTROKES AND MOUSE ACTIONS. ONCE THE ONE IMAGE IS FROZEN IN A VIEWPORT IT REMAINS FROZEN. IT WILL ALSO REMAIN FROZEN IF […]
Where this fits
This page is a record, not medical advice and not a safety rating. It copies FDA's fields and FDA's statement, and lists what the statement's text mentions. Read the labeling before relying on any of it.
More devices under product code POK, in Radiology, or cleared in 2022. The whole record is at FDA AI-enabled medical devices.
A device's authorized use is a sentence the record can be read against. What Apodicta does on a medical record is that reading: every line of a note, a claim or a report proved to its source or held, before it renders.