Radiology · 510(k) · 2024
ACUSON Sequoia Diagnostic Ultrasound System; ACUSON Sequoia Select Diagnostic Ultrasound System; ACUSON Origin Diagnostic Ultrasound System; ACUSON Origin ICE Diagnostic Ultrasound System
Siemens Medical Solutions USA, Inc.. Cleared by FDA on 19 November 2024 under submission K242523, product code IYN (system, imaging, pulsed doppler, ultrasonic). What FDA's record says, in FDA's words.
Device record · K242523
- Device. ACUSON Sequoia Diagnostic Ultrasound System; ACUSON Sequoia Select Diagnostic Ultrasound System; ACUSON Origin Diagnostic Ultrasound System; ACUSON Origin ICE Diagnostic Ultrasound SystemDEVICE
- Company. Siemens Medical Solutions USA, Inc.COMPANY
- Decision. 19 November 2024, 510(k), substantially equivalent (traditional review); received 23 August 2024DECISION
- Panel. RadiologyPANEL
- Product code. IYN, System, Imaging, Pulsed Doppler, UltrasonicCODE
- Regulation. 21 CFR 892.1550, Class IIREG
- Source. FDA database entry · decision document (16 pages)SOURCE
Retrieved · the fields above are FDA's; the statement below was copied from the decision document on that day.
What FDA cleared it for
The Indications for Use statement, verbatim, from the decision document.
ACUSON Sequoia and ACUSON Sequoia Select The ACUSON Sequoia and Sequoia Select ultrasound imaging systems are intended to provide images of, or signals from, inside the body by an appropriately trained healthcare professional in a clinical setting for the following applications: Fetal, Abdominal, Pediatric, Neonatal Cephalic, Small Parts, OB/GYN (useful for visualization of the ovaries, follicles, uterus and other pelvic structures), Cardiac, Pelvic, Vascular, Adult Cephalic, Musculoskeletal and Peripheral Vascular applications. The system supports the Ultrasonically-Derived Fat Fraction (UDFF) measurement tool to report an index that can be useful as an aid to a physician managing adult and pediatric patients with hepatic steatosis. The system also provides the ability to measure anatomical structures for fetal, abdominal, pediatric, small organ, cardiac, transrectal, transvaginal, peripheral vessel, Siemens Medical Solutions USA,Inc. Ultrasound Division ACUSON Sequoia, SequoiaSelect, Origin and Origin ICE Diagnostic Ultrasound System 510(k) Submission ACUSON Sequoia, Sequoia Select, Origin and Origin ICE Diagnostic Ultrasound System 510(k) Submission musculoskeletal and calculation packages that provide information to the clinician that may be used adjunctively with other medical data obtained by a physician for clinical diagnosis purposes. Operating Modes 2D-mode 2D-mode 2D-mode with Harmonics Imaging 2D-mode with Harmonics Imaging for Contrast Agent Imaging […]
What the statement says
Pattern matches on the Indications for Use text. Each line is a fact that the text contains the words, not a finding about the device.
- Modalities namedultrasound
- Mentionsan adjunct to the clinician, not a replacement
- Mentionsmeasurement or quantification
- Mentionsa diagnostic claim
- Mentionsadult patients
- Mentionspediatric patients
Adverse-event reports in MAUDE, by product code
As of , MAUDE held 2,748 reports filed against devices carrying product code IYN. That code is shared by every device of this type, not this device alone, and MAUDE reports are submitted by manufacturers, facilities and the public without FDA verification. The latest reports, in the reporter’s words:
30 September 2026 · Malfunction · ACUSON Origin Ultrasound System · Siemens Medical Solutions USA, Inc. · report 3023245-2026-00096
30 September 2026 · Malfunction · ACUSON Sequoia Ultrasound System · Siemens Medical Solutions USA, Inc. · report 3023245-2026-00097
30 September 2026 · Malfunction · AFFINITI 30 · Philips Ultrasound, Inc · report 3019216-2026-100325
30 September 2026 · Injury · EPIQ 5G · Philips Ultrasound, Inc · report 3019216-2026-100326
29 September 2026 · Malfunction · ACUSON Juniper · Siemens Medical Solutions USA, Inc. · report 3023245-2026-00091
One of the patient exams performed on the Juniper system displays an "Unarchived" error message and they are unable to send this study to PACS. All other exams performed before are after this one are transferring over to the PACS as expected without any errors. The problem occurred after a Breast study was completed and the user tried to send it over to the network PACS. TSE worked with the customer and she confirmed that the problem cannot be reproduced, as it only is affecting this one exam. […]
Where this fits
This page is a record, not medical advice and not a safety rating. It copies FDA's fields and FDA's statement, and lists what the statement's text mentions. Read the labeling before relying on any of it.
More devices under product code IYN, in Radiology, from Siemens Medical Solutions USA, Inc., or cleared in 2024. The whole record is at FDA AI-enabled medical devices.
A device's authorized use is a sentence the record can be read against. What Apodicta does on a medical record is that reading: every line of a note, a claim or a report proved to its source or held, before it renders.